Incineration: Combustor® Fixed Bed Furnace
Main data:
| Kind of waste: | Domestic waste Industrial waste Chemical residues Hospital waste Solid Paste-like up to 30% moisture content Incineration of liquid waste |
| Amount of waste: | 10 - 5.300 kg/h |
| Calorific value of waste: | 1 - 45 MJ/kg |
| Density of waste: | 50 - 1.250 kg/m3 |
Features:
- Simple and rigid construction: use of standard units
- Incineration without grate: absolutely sterile ashes by a complete
burnout in the combustion chamber - Post-combustion chamber: elimination of odour and organic matters
- Low heat emission: additional-leaf furnance structure
- Refractory lining: wear resistant and heat storing refractory lining,
low surface temperature of the furnace - Low required space: two-stage incineration, integrated in one housing, compact construction
- Easy operability: automatic function control, large firing and ash discharging openings, optionally automatic charging and ash discharging systems
- Low maintenance costs: all important components are clearly arranged and easy of access, standard compontents
- Mobile incineration system: installation in ISO standard containers
- Made in Germany Qualität: long-life cycle
Technical data:
| Type | Cd1 | Cd2 | Cd3 | Cd4 | Cd5 | Cd6 | Cd7 | Cd8 | Cd9 |
| Capacity kg/h | 20 | 35 | 50 | 75 | 100 | 150 | 200 | 250 | 300 |
| Thermal capacity | 70 | 125 | 175 | 265 | 350 | 525 | 700 | 875 | 1.050 |
| Main combustion chamber | |||||||||
| Temperature °C | 600 - 1.200 | ||||||||
| Residence time of waste Minutes |
30 - 60 | ||||||||
| Postcombustion chamber | |||||||||
| Temperature °C | 800 - 1.200 | ||||||||
| Residence time of flue gas Seconds |
> 2 | ||||||||
Each incineration system will be adapted to the local requirements by Michaelis. The data indicated on the table are reference values. The data are calculated with a calorific value of 12.500 kJ/kg and a moisture content less than 10%. With the composition of the waste the indicated data will change.